Home / Products / VitaloLAB

VitaloLAB

Full pulmonary function testing, including spirometry, DLco, and respiratory muscle assessments

$1.00

The ground-breaking VitaloLAB™ combines power and precision in one unique full pulmonary function testing system. Designed to be compliant with latest international guidelines for accuracy, repeatability and grading. The impressive VitaloLAB PFT system gives you full spirometry, provocation, DLco (RGA), lung volume measurements, lung clearance index (LCI) and respiratory muscle assessments as standard plus many more features that will blow you away.

Click here for reimbursement codes for Vitalograph Devices in the USA.

Product code: 9100

  • The ideal PFT lab solution with complete testing options available
  • Powered by the first-in-class ComPAS2 software.
  • Stay connected with simple workflows with ComPAS2 Task Manager
Model 9100 Vitalograph Morgan VitaloLAB
Model Number9100
Essential Performance Test LimitsData will be transferred by USB from the device PCBs to the on-board computer. The output from the DLco Gas Analyser must stay within the predetermined limits (see below) both in normal and single fault conditions.
  • Carbon Monoxide (CO) values in DLco Gas Analyser: +/- 30 counts
  • Methane (CH4) values in DLco Gas Analyser: +/- 75 counts
Flow Detection PrincipalHeated Lilly type pneumotachography
Back pressureLess than 0.15kPa/L/second @ 14L/s, complies with ISO26782:2009)
Volume detectionFlow integration sampling @ 100Hz
Volume AccuracyWithin ±2.5% or ±75 mL
Voltage/Frequency80-240V; approximately 50/60 Hz
Flow accuracyWithin ±2% over the range of -14 to +14 L/s
Flow measurement rangeMax. flow rate ±14 L/s
Min. flow rate ±0.2 L/s
Operating temperature rangeISO26782 limits: 17–37ºC
Design limits: 15–37ºC
Operating humidity range30%–75%
Ambient pressure range850hPa–1060hPa
Gas Analyser for CO/CH4Nondispersive infrared (NDIR) sensor.
Accuracy:
CO ±1 % of Full Scale
CH4 ±2.5 % of Full Scale
Gas Analyser for O2/CO2Laser diode absorption for O2.
Infrared sensor for CO2
Accuracy:
O2 +/- 0.2%
CO2 +/- 0.1%
Shutter ValvePneumatic spring-return cylinder
Gas required for DLco testMix containing 0.3% Carbon Monoxide, 0.3% Methane, Balance Air
Gases required for SBN2 and MBN2 tests
  • Mix containing 0.3% Carbon Monoxide, 0.3% Methane, Balance Air
  • 100% Oxygen
  • Mix containing 3-6% Carbon Dioxide, 13-16% Oxygen, balance Nitrogen
Performance standards the Vitalograph VitaloLAB meets or exceedsISO 23747:2015, ISO 26782 2009, ATS/ERS 2019 Technical Standards
Safety standardsEN 60601-1:2006 + A1:2013
EMC standardsEN 60601-1-2:2015
QA/GMP standardsEN ISO 13485
Size500 mm x 395 mm x 135 mm
Weight9 kg
PrinterExternal
CommunicationsUSB Hub, 1 x USB B Connection
SoftwareMorgan Scientific ComPAS2 general PC requirements:
  • Windows 10 Pro or Enterprise (64 bit)
  • Processor/CPU: Minimum 8th generation Intel Core i5; latest generation Intel Core i5 Recommended
  • Minimum 8GB RAM; 16GB RAM Recommended
  • Minimum resolution 1920 width and 1080 height (both are required)
  • Minimum 15.6” screen size; 24” Recommended
  • 16:9 Aspect Ratio
  • Three available USB ports, fully powered type A USB port (2.0 or better)
  • Integrated audio or dedicated sound card with 3.5mm audio mic and audio output

Storage: SATA or NVMe SSD recommended. PC testing station local machine storage requirements vary based on deployment environment. Generally, if SQL database is to reside on the local machine, more storage is recommended than if the SQL database is to reside on a central server. General guidelines:
  • 1GB local storage for software installation
  • Local storage of SQL database: ≥500GB, SSD Only
  • Central storage of SQL database: ≥200GB, 7200RPM HDD or SSD
  • SSDs result in notable performance improvement over HDDs

Product Specification

 Pneumotrac with Spirotrac (PC Based)
Tests:
VC
FVC
Post BD
Total Parameters Available60
Quality Measures & Incentives:
Predicted Values
Interpretation
Quality Prompts
Incentives
Data Exchange & Printing:
In-Built Printer
PDF Reports (V=Vitalograph Reports, S=Spirotrac) S
Bi-directional Data Exchange with EMRs
General Features:
Touch Screen
Colour Display
Internal Battery
Full Database
Add-On Test Module Options:
Pulse Oximetry
Resting 12 lead ECG

FAQs

The VitaloLAB PFT system offers a comprehensive range of features, including full spirometry, provocation, DLco (RGA), lung volume measurements, lung clearance index (LCI), and respiratory muscle assessments. It exceeds international guidelines for accuracy, repeatability, and grading.

The VitaloLAB PFT system is specifically designed to be compliant with the latest international guidelines. It undergoes rigorous testing and calibration processes to ensure accuracy, repeatability, and grading, making it a reliable choice for pulmonary function testing.

Yes, the VitaloLAB PFT system offers a range of standard features, but it can also be customized or expanded with additional functionalities based on specific clinic requirements. This flexibility allows clinic operators to tailor the system to their needs and maximize its capabilities

Talk to Us

For information on any of our products, click the inquiry button, enter your query and we will get back to you.

Talk to Us

For information on any of our products, click the inquiry button, enter your query and we will get back to you.

Get A Quote